E0A01

What is the primary function of an external earth connection or ground rod?

AnswerLightning charge dissipation

An external earth connection or ground rod provides a path for lightning charge to dissipate into the earth. It is not the primary means for controlling RF current between pieces of station equipment.

E0A02

When evaluating RF exposure levels from your station at a neighbor’s home, what must you do?

AnswerEnsure signals from your station are less than the uncontrolled maximum permissible exposure (MPE) limits

A neighbor is part of the general public, so exposure at the neighbor's home must remain below the uncontrolled maximum permissible exposure limits.

E0A04

When evaluating a site with multiple transmitters operating at the same time, the operators and licensees of which transmitters are responsible for mitigating over-exposure situations?

AnswerEach transmitter that produces 5 percent or more of its MPE limit in areas where the total MPE limit is exceeded

At a multi-transmitter site where the combined exposure exceeds the MPE limit, responsibility extends to each transmitter contributing at least 5 percent of its own applicable MPE limit in the affected area.

E0A05

What hazard is created by operating at microwave frequencies?

AnswerThe high gain antennas commonly used can result in high exposure levels

Microwave systems commonly use high-gain antennas that concentrate RF energy into a narrow beam. That concentration can produce high exposure levels even when transmitter power is not unusually high.

E0A06-A

Why must RF exposure limits below 300 MHz account for both electric and magnetic fields?

AnswerThe body reacts to electromagnetic radiation from both the E and H fields.

The official E0A06 source identifies the body's response to both electric and magnetic field components as one reason separate E-field and H-field MPE limits are used below 300 MHz.

E0A06-B

Why can RF field strength vary significantly with location below 300 MHz?

AnswerGround reflections and scattering cause the field strength to vary with location.

The official E0A06 source identifies ground reflections and scattering as a reason RF field strength can vary from one location to another.

E0A06-C

Why can separate electric-field and magnetic-field measurements be important below 300 MHz?

AnswerE-field and H-field radiation intensity peaks can occur at different locations.

The official E0A06 source identifies the possibility that electric- and magnetic-field peaks occur in different places, so one measurement does not necessarily represent the other.

E0A07

What is meant by “100% tie-off” regarding tower safety?

AnswerAt least one lanyard attached to the tower at all times

One-hundred-percent tie-off means the climber always has at least one lanyard connected to the tower while transitioning between attachment points.

E0A08

What does SAR measure?

AnswerThe rate at which RF energy is absorbed by the body

Specific Absorption Rate, or SAR, measures the rate at which RF energy is absorbed by the human body.

E0A11

To what should lanyards be attached while climbing?

AnswerTower legs

While climbing, lanyards should be attached to structural tower legs rather than to rungs, guy brackets, or the antenna mast.